Orthopaedic Implant Manufacturer
img08045812906
Radial Head Rim Plate
Radial Head Rim Plate

Radial Head Rim Plate

MOQ : 100 Pieces

Radial Head Rim Plate Specification

  • Implants Type
  • Orthopedic Implant
  • Material
  • Steel
  • Sterilized
  • Yes
  • Sterilization Mode
  • Gamma Radiation
  • Stent Location
  • Radial Head (Elbow)
  • Physical Shape
  • Rim Plate (Anatomic Contoured)
  • Curved Angle
  • Anatomic Curvature for Radial Head
  • Flexible
  • Yes
  • Soluble
  • No
  • Recyclable
  • Yes
  • Recommended For
  • Radial Head Fracture Fixation
  • Usage
  • Hospital
  • Dimension (L*W*H)
  • Approx. 36 mm x 10 mm x 2.5 mm
  • Diameter
  • Approximately 18 mm (rim curvature)
  • Head Diameter
  • Designed for variable patient anatomy
  • Length
  • 36 mm
  • Grade
  • A
  • Color
  • Metallic Silver
  • Weight
  • Approx. 7 grams
  • Attachment
  • Pre-drilled Holes for Locking/Non-locking Screws
  • Radiolucency
  • Not radiolucent (metallic)
  • Number of Holes
  • 5 to 7 holes (depending on variant)
  • Technique
  • Open Reduction Internal Fixation (ORIF)
  • Surface Finish
  • Anodized/Satin Smooth
  • Packaging
  • Individually packed & sterilized pouch
  • Usage Site
  • Proximal Radius
  • MRI Compatibility
  • Yes, Non-magnetic
  • Screw Compatibility
  • 2.0 mm or 2.4 mm locking and non-locking screws
  • Shelf Life
  • 5 years in original packaging
 

Radial Head Rim Plate Trade Information

  • Minimum Order Quantity
  • 100 Pieces
  • Payment Terms
  • Cash in Advance (CID)
  • Supply Ability
  • 5000 Pieces Per Week
  • Delivery Time
  • 3-7 Days
  • Main Domestic Market
  • All India
 

About Radial Head Rim Plate

A Radial Head Rim Plate is a specific type of medical implant used in orthopedic surgery to treat fractures and other injuries involving the radial head, which is the round-shaped bone at the top of the radius bone in the forearm. The radial head plays an important role in the stability and movement of the elbow joint. The Radial Head Rim Plate is designed to provide stability and support to the fractured radial head, facilitating the healing process and restoring proper function of the elbow joint. 


Advanced Design for Precise Fixation

This rim plate boasts an anatomic curvature tailored for the radial head, providing optimal fit and stability during fracture fixation. The pre-drilled holes are designed for use with both 2.0 mm and 2.4 mm screws, accommodating a variety of surgical needs and patient anatomies. Its contoured profile aids in preserving natural joint function post-procedure.


Highly Durable and Safe for Imaging

Manufactured from non-magnetic steel, the rim plate is safe for MRI and does not interfere with post-operative imaging. It features a metallic silver, anodized surface that resists corrosion and enhances durability. The implant's strength and biocompatibility make it suitable for Grade A hospital use.


Sterile and Convenient Packaging

Each radial head rim plate is individually pouched and sterilized using gamma radiation, ensuring surgical readiness and reducing infection risk. With a 5-year shelf life in original packaging, hospitals and surgical centers can rely on consistent quality and availability.

FAQ's of Radial Head Rim Plate:


Q: How is the Radial Head Rim Plate used in surgery?

A: The Radial Head Rim Plate is used in open reduction internal fixation (ORIF) procedures to stabilize fractures of the radial head. It is anatomically contoured to fit the radial head and secured using 2.0 mm or 2.4 mm locking or non-locking screws.

Q: What screw sizes are compatible with this rim plate?

A: This rim plate is compatible with both 2.0 mm and 2.4 mm diameter locking or non-locking screws, offering flexibility for various clinical situations and surgeon preferences.

Q: When should a surgeon choose this implant?

A: This plate is recommended when precise, stable fixation is required for fractures of the radial head-commonly in traumatic elbow injuries needing anatomical restoration.

Q: Where is the implant positioned during surgery?

A: The rim plate is positioned on the proximal radius, specifically the radial head, aligning with its anatomic contour to ensure secure fixation and preserve joint mobility.

Q: What is the sterilization process for this product?

A: Each plate is sterilized using gamma radiation and packed in an individual sterilized pouch, maintaining aseptic conditions until use.

Q: What are the benefits of using this rim plate?

A: Benefits include an anatomic fit, compatibility with multiple screw types, MRI compatibility, corrosion resistance, and a surface finish that minimizes soft tissue irritation, promoting optimal surgical outcomes.

Q: Is the plate recyclable or environmentally friendly?

A: Yes, the plate is fully recyclable after its clinical use, aligning with environmentally responsible practices in medical facilities.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Orthopedic Locking Plate Category

3.5Mm Proximal Humerus Plate

3.5Mm Proximal Humerus Plate

Minimum Order Quantity : 100 Pieces

Material : Steel

Implants Type : Other, Orthopedic Plate

Color : Metallic (Silver or Blue for Titanium)

Sterilized : Yes

Usage : Hospital

AS Spanning Plate (standard Bend)

AS Spanning Plate (standard Bend)

Minimum Order Quantity : 100 Pieces

Material : Steel

Implants Type : Metal Plates

Color : Silver

Sterilized : Yes

Usage : Hospital

QuadriLateral Acetabular Plate

QuadriLateral Acetabular Plate

Minimum Order Quantity : 100 Pieces

Material : Steel

Implants Type : Metal Plates

Color : Silver

Sterilized : Yes

Usage : Hospital

PEDIATRIC DHS PLATE(ROUND HOLE)

PEDIATRIC DHS PLATE(ROUND HOLE)

Minimum Order Quantity : 100 Pieces

Material : Steel

Implants Type : Metal Plates

Color : Silver

Sterilized : Yes

Usage : Hospital



arrow